Remote Mount 5-Valves Manifolds, Model-HM8532
Using the 5-valve manifold_x000d_
_x000d_
In normal operation the “isolate” valves are open while the “equalize” and “vent” valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter._x000d_
_x000d_
To zero the instrument, first close both “vent” valves and the downstream “isolate” valve. Then open the “equalize” valve and adjust the zero setting on the instrument._x000d_
_x000d_
To remove the instrument, first close both “isolate” valves, then open the “equalize” valves to relieve pressure between the manifold and the instrumet._x000d_
_x000d_
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
Scarica il PDF tecnico
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Per poter scaricare i PDF deve essere registrato o fare login al nostro catalogo
Hoke, Gyrolok